wiring diagram AUDI A4 1999 B5 / 1.G AWM Engine Oxygen Sensor Control Checking Workshop Manual

Page 13 of 46

24-83


Electrical Wiring Diagrams, Troubleshooting & Component Locations
If wire connection is OK: - Check the following wire connections for open circuit.Harness connector
Terminal
VAG1598/31 test box
Socket
1 70
2 71
5 51
6 52
- Repair open circuit if necessary.- Check wires to each other for short circuit.
- Replace Engine Control Module (ECM) Page 24
-22
Pa
ge 13 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2

Page 20 of 46

24-90

Test requirements:

Coolant Temperature at least 80 C.

Fuse for oxygen sensor heating OK

Electrical Wiring Diagrams, Troubleshooting &
Component Locations

Test sequence

Note:
Coolant reservoir screws must be removed and coolant reservoir must be
placed to side in order to access the harness connector. The coolant
hoses can remain connected. - Disconnect 6-pin harness connector (black) -2- to Heated Oxygen
Sensor (HO2S) -G39- before catalytic converter.

If specified value is not obtained: - Connect multimeter between terminal 3 and 4 for resistance
measurement.

Specified value at room temperature: 2.5 to 10
Pa
ge 20 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2

Page 23 of 46

24-92

- Operate starter briefly.


Specification: approx. battery voltage
If there is no voltage again:

- Check wire connection from terminal 3 of
connector to Fuel Pump (FP) relay via fuse for
open circuit:

Electrical Wiring Diagrams, Troubleshooting &
Component Locations
If voltage supply is OK:

Note: - Connect multimeter for voltage measurement as follows:Harness connector
Terminal
Measure
to
4 (Ground -GND- activation of Engine Control Module -
ECM-) B+
- Start engine.

Specification: approx. battery voltage
Pa
ge 23 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2

Page 25 of 46

24-93

- Switch ignition off.
If there is no voltage:

- Connect VAG1598/31 test box at wiring harness
to Engine Control Module (ECM), do not connect
ECM Page 24
-19
.

Electrical Wiring Diagrams, Troubleshooting & Component Locations
If wire connection is OK, but there is no Ground (GND) supply for oxygen
sensor heating: - Check the following wire connection for open circuit:Harness connector
Terminal
VAG1598/31 test box
Socket
4 5
- Repair open circuit if necessary.- Replace Engine Control Module (ECM) Page 24
-22
Pa
ge 25 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2

Page 38 of 46

24-106


Electrical Wiring Diagrams, Troubleshooting & Component Locations
If wire connection is OK: - Check the following wire connections for open circuit.Harness connector
Terminal
VAG1598/31 test box
Socket
3 68
4 69
- Repair open circuit if necessary.- Check wires to each other for short circuit.
- Replace Engine Control Module (ECM) Page 24
-22
Pa
ge 38 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2

Page 40 of 46

24-108

Test requirements:

Coolant Temperature at least 80 C.

Fuse for oxygen sensor heating OK

Electrical Wiring Diagrams, Troubleshooting &
Component Locations

Test sequence

Note:
Coolant reservoir screws must be removed and coolant reservoir must be
placed to side in order to access the harness connector. The coolant
hoses can remain connected. - Disconnect 4-pin harness connector -1- (brown) to Oxygen Sensor
(O2S) behind Three Way Catalytic Converter (TWC) -G130-.

If specified value is not obtained: - Connect multimeter between terminal 1 and 2 for resistance
measurement.

Specified value at room temperature: 6.4 to 47.5
Pa
ge 40 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2

Page 43 of 46

24-110

- Operate starter briefly.


Specification: approx. battery voltage
If there is no voltage again:

- Check wire connection from terminal 1 of
connector to Fuel Pump (FP) relay via fuse for
open circuit:

Electrical Wiring Diagrams, Troubleshooting &
Component Locations
If voltage supply is OK:

- Connect multimeter for voltage measurement as follows:Harness connector
Terminal
Measure
to
2 (Ground -GND- activation of Engine Control Module -
ECM-) B+
- Start engine.

Specification: approx. battery voltage, possibly fluctuating
- Switch ignition off.
Pa
ge 43 of 46 Ox
yg
en sensor control, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU07.24.2